  • ISO 11135-1:2007
    衛生保健品滅菌.環氧乙烷.第1部分:醫療設備消毒過程的制定、確認和常規控制的要求

    Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices


    標準號
    ISO 11135-1:2007
    發布
    2007年
    中文版
    GB 18279.1-2015 (等同采用的中文版本)
    發布單位
    國際標準化組織
    當前最新
    ISO 11135-1:2007
     
     
    引用標準
    ISO 10012 ISO 10993-1 ISO 10993-7 ISO 11138-1:2006 ISO 11138-2:2006 ISO 11140-1 ISO 11737-1 ISO 11737-2 ISO 13485:2003 ISO 14161 ISO 14937:2000
    適用范圍
    This part of ISO 11135 specifies requirements for the development, validation and routine control of an ethylene oxide sterilization process for medical devices. NOTE 1 Although the scope of this part of ISO 11135 is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other health care products. Sterilization processes validated and controlled in accordance with the requirements of this part of ISO 11135 are not assumed to be effective in inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeld Jacob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. NOTE 2 See for example ISO 22442-1, ISO 22442-2 and ISO 22442-3. This part of ISO 11135 does not detail a specified requirement for designating a medical device as sterile. NOTE 3 Attention is drawn to national or regional requirements for designating medical devices as “sterile”. See for example EN 556-1 or ANSI/AAMI ST67. This part of ISO 11135 does not specify a quality management system for the control of all stages of production of medical devices. NOTE 4 The effective implementation of defined and documented procedures is necessary for the development, validation and routine control of a sterilization process for medical devices. Such procedures are commonly considered to be elements of a quality management system. It is not a requirement of this part of ISO 11135 to have a complete quality management system during manufacture or reprocessing, but the elements of a quality management system that are the minimum necessary to control the sterilization process are normatively referenced at appropriate places in the text (see in particular Clause 4). National and/or regional regulations for the provision of medical devices might require implementation of a complete quality management system and the assessment of that system by a third party. This part of ISO 11135 does not specify requirements for occupational safety associated with the design and operation of ethylene oxide sterilization facilities. NOTE 5 For further information on safety, see examples in the Bibliography. National or regional regulations may also exist. NOTE 6 Ethylene oxide is toxic, flammable and explosive. Attention is drawn to the possible existence in some countries of regulations giving safety requirements for handling ethylene oxide and for premises in which it is used. This part of ISO 11135 does not cover sterilization by injecting ethylene oxide or mixtures containing ethylene oxide directly into individual product packages, or continuous sterilization processes.

    ISO 11135-1:2007相似標準


    推薦

    關于批準發布《棉花 1部分:鋸齒加工細絨棉》等21項強制性國家標準公告

    醫療保健產品滅菌 環氧乙烷 醫療器械滅菌過程開發、確認常規控制要求 醫療保健產品滅菌 環氧乙烷 醫療器械滅菌過程開發、確認常規控制要求 GB 18279.1-2015,GB/T 18279.2-2015 2026-...

    紫外/可見分光光度計在應對新冠狀病毒性肺炎防疫檢測中應用

    No.6試驗用設備實驗所用儀器“上海元析儀器有限公司生產UV-8000T觸屏版雙光束紫外可見分光光度計”No.7補記《GB/T 16886.7-2015 醫療器械生物學評價 7部分環氧乙烷滅菌殘留量》中對環氧乙烷殘留量測定(4.4.2條)中提到EO殘留量測定方法有多種,只要表明其分析可靠(即有一定準確度、精密度、線性、靈敏度選擇性)并經過確認即可采用。...

    衛計委發布關于征求消毒產品衛生安全評價規定

    相關國家標準、GB28232《臭氧發生器安全與衛生標準》、GB28931《二氧化氯消毒劑發生器安全與衛生標準》、GB18281.1《醫療保健產品滅菌 生物指示物 1部分:通則》要求、 GB18281.2《醫療保健產品滅菌 生物指示物 2部分環氧乙烷滅菌用生物指示物》、GB18281.3《醫療保健產品滅菌 生物指示物 3部分:濕熱滅菌用生物指示物》、GB18282.1《醫療保健產品滅菌...

    環氧乙烷檢測方法

    1 簡述 ?相關醫療設備在生產后滅菌工藝,是常規必須標準過程控制要求,但對其中用EO滅菌工藝產品,一定按標準對其質量嚴格控制,并達到國家標準質量控制要求。但對于醫療防護設備安全篩查及快檢提出了嚴格控制標準及要求,對檢測設備準確定量、快速定性提出了新技術指標。...