• <li id="ccaac"></li>
  • <table id="ccaac"><rt id="ccaac"></rt></table>
  • <td id="ccaac"></td>
  • <td id="ccaac"></td>
  • BS DD CEN/TS 14507-1-2003
    氮氧化物吸入系統.輸送系統

    Inhalational nitric oxide systems. Delivery systems


    BS DD CEN/TS 14507-1-2003 發布歷史

    This Part of CEN/TS 14507 refers to EN 60601-1:1990 "Medical electrical equipment — Part 1: General requirements for safety", as amended by its amendments 1 (1991) and 2 (1995). For brevity Part 1 is referred to in this Part of CEN/TS 14507 either as the General Standard or as the General requirements. The scope given in clause 1 of the General Standard applies except that 1.1 is replaced by the following: 1.1 This Part of CEN/TS 14507 specifies particular requirements for inhalational nitric oxide delivery systems and their modules. It covers devices which can be supplied in combined units, integrated into another medical device, for example a lung ventilator, or as individual devices. This Part of CEN/TS 14507 addresses the monitoring of nitric oxide and oxygen delivery to the patient and minimization of the production of nitrogen dioxide. This Part of CEN/TS 14507 covers the requirements for inhalational nitric oxide delivery systems intended for medical use, for example, in critical care, anaesthesia, and emergency/transport environments. NOTE It is recognized that from time to time innovations and designs will appear that offer advantages and yet are not covered by specific safety-related design or performance aspects of this Part of CEN/TS 14507; such innovations are not to be discouraged. As the techniques and technologies in these innovations advance, it is essential that the safety objectives of this Part of CEN/TS 14507 are considered as minimum requirements. The requirements of clause 1.3 of the General Standard apply with the following additions: The numbering of clauses and subclauses of this Part of CEN/TS 14507 corresponds to that of the General Standard. The changes to the text of the General Standard are specified by the use of the following words: ′Replacement′ means that the clause or subclause of the General Standard is replaced completely by the text of this Part of CEN/TS 14507. ′Addition′ means that the text of this Part of CEN/TS 14507 is additional to the requirements of the General Standard. ′Amendment′ means that the clause or subclause of the General Standard is amended as indicated by the text of this Part of CEN/TS 14507. Subclauses or figures which are additional to those of the General Standard are numbered starting from 101. Additional annexes are lettered AA, BB, etc. and additional items aa), bb), etc. The term ′this Standard′ is used to make reference to the General Standard and this Part of CEN/TS 14507 taken together. Where there is no corresponding section, clause or subclause in this Part of CEN/TS 14507, the section, clause or subclause of the General Standard applies without modification. Where it is intended that any part of the General Standard, although possibly relevant, is not to be applied, a statement to that effect is given in this Part of CEN/TS 14507.

    BS DD CEN/TS 14507-1-2003由英國標準學會 GB-BSI 發布于 2003-04-11,并于 2003-04-11 實施。

    BS DD CEN/TS 14507-1-2003 在中國標準分類中歸屬于: C47 公共醫療設備,在國際標準分類中歸屬于: 11.040.10 麻醉、呼吸和復蘇設備。

    BS DD CEN/TS 14507-1-2003 發布之時,引用了標準

    • EN 60601-1-6 醫用電氣設備.第1-6部分:基本安全和重要性能的一般要求.附屬標準:可用性*2010-04-01 更新
    • EN 60601-1-1990 醫療電氣設備.第1部分:安全性的一般要求.(包括修改件A1-1993,A11-1993,A12-1993,A2-1995和A13-1996.包括1994年7月勘誤表.包括2005年8月勘誤表.IEC 60601-1-1988 + A1-1991 + A2-1995 + c)
    • EN 738-1-1997 
    • EN 738-3-1998 
    • EN 739-1998 醫療用氣體設備的低壓軟管組件.包含修改件A1-2002
    • EN 12598 
    • EN 13221 
    • EN 60068-2-64-1994 環境試驗.第2部分:試驗方法.試驗Fh:寬帶隨機振動(數控)和指南(IEC 68-2-64-1993 + corrigendum 1993)

    * 在 BS DD CEN/TS 14507-1-2003 發布之后有更新,請注意新發布標準的變化。

    BS DD CEN/TS 14507-1-2003的歷代版本如下:

    BS DD CEN/TS 14507-1-2003



    標準號
    BS DD CEN/TS 14507-1-2003
    發布日期
    2003年04月11日
    實施日期
    2003年04月11日
    廢止日期
    中國標準分類號
    C47
    國際標準分類號
    11.040.10
    發布單位
    英國標準學會
    引用標準
    CR 13903 EN 60601-1-6 prEN ISO 407-2001 ISO/DIS 5145-2001 NFPA publication 53M EN 60601-1-1990 EN 475 EN 738-1-1997 EN 738-1-1997/A1-2001 EN 738-3-1998 EN 738-3-1998/A1-2001 EN 739-1998 N 739-1998/A1-2001 EN 12598 EN 13221 EN 60068-2-64-1994 IE
    適用范圍
    This Part of CEN/TS 14507 refers to EN 60601-1:1990 "Medical electrical equipment — Part 1: General requirements for safety", as amended by its amendments 1 (1991) and 2 (1995). For brevity Part 1 is referred to in this Part of CEN/TS 14507 either as the General Standard or as the General requirements. The scope given in clause 1 of the General Standard applies except that 1.1 is replaced by the following: 1.1 This Part of CEN/TS 14507 specifies particular requirements for inhalational nitric oxide delivery systems and their modules. It covers devices which can be supplied in combined units, integrated into another medical device, for example a lung ventilator, or as individual devices. This Part of CEN/TS 14507 addresses the monitoring of nitric oxide and oxygen delivery to the patient and minimization of the production of nitrogen dioxide. This Part of CEN/TS 14507 covers the requirements for inhalational nitric oxide delivery systems intended for medical use, for example, in critical care, anaesthesia, and emergency/transport environments. NOTE It is recognized that from time to time innovations and designs will appear that offer advantages and yet are not covered by specific safety-related design or performance aspects of this Part of CEN/TS 14507; such innovations are not to be discouraged. As the techniques and technologies in these innovations advance, it is essential that the safety objectives of this Part of CEN/TS 14507 are considered as minimum requirements. The requirements of clause 1.3 of the General Standard apply with the following additions: The numbering of clauses and subclauses of this Part of CEN/TS 14507 corresponds to that of the General Standard. The changes to the text of the General Standard are specified by the use of the following words: ′Replacement′ means that the clause or subclause of the General Standard is replaced completely by the text of this Part of CEN/TS 14507. ′Addition′ means that the text of this Part of CEN/TS 14507 is additional to the requirements of the General Standard. ′Amendment′ means that the clause or subclause of the General Standard is amended as indicated by the text of this Part of CEN/TS 14507. Subclauses or figures which are additional to those of the General Standard are numbered starting from 101. Additional annexes are lettered AA, BB, etc. and additional items aa), bb), etc. The term ′this Standard′ is used to make reference to the General Standard and this Part of CEN/TS 14507 taken together. Where there is no corresponding section, clause or subclause in this Part of CEN/TS 14507, the section, clause or subclause of the General Standard applies without modification. Where it is intended that any part of the General Standard, although possibly relevant, is not to be applied, a statement to that effect is given in this Part of CEN/TS 14507.

    BS DD CEN/TS 14507-1-2003系列標準





    Copyright ?2007-2022 ANTPEDIA, All Rights Reserved
    京ICP備07018254號 京公網安備1101085018 電信與信息服務業務經營許可證:京ICP證110310號



  • <li id="ccaac"></li>
  • <table id="ccaac"><rt id="ccaac"></rt></table>
  • <td id="ccaac"></td>
  • <td id="ccaac"></td>
  • 床戏视频