This document specifies constructional, functional, testing and marking requirements, sizing and documentation of gas safety shut-off devices used in the pressure regulating stations in accordance with EN 12186 or EN 12279: - for inlet pressures up to 100 bar and nominal diameters up to DN 400; - for an operating temperature range from –20 °C to +60 °C, which operate with fuel gases of the 1st and 2nd family in accordance with EN 437 in transmission and distribution networks and also in commercial and industrial installations. "Gas safety shut-off devices" will hereafter be called "SSDs" except in titles. For standard safety shut-off devices when used in pressure regulating stations complying with EN 12186 or EN 12279, Annex ZA lists all applicable Essential Requirements except the external corrosion resistance in case of environmental conditions where corrosion is likely to occur." This document considers the following classes/types of SSDs: temperature classes: - class 1: operating temperature range from –10 °C to 60 °C; - class 2: operating temperature range from –20 °C to 60 °C; functional classes: -class A: SSDs that close when damage to the pressure detector element occurs (applicable to overpressure SSDs only) or when external power fails and whose re-opening, after an intervention for overpressure, is possible only manually; - class B: SSDs that do not close when damage to the pressure detector element occurs and whose reopening, after an intervention for overpressure, is possible only manually; SSDs types: - type IS: (integral strength type); - type DS: (differential strength type). SSDs complying with the requirements of this document may be declared as “in conformity with EN 14382“ and bear the mark “EN 14382”. The material and functional requirements specified in this document may be applied to SSDs which use thermal energy or the effects of electrical energy to trip the operation of the closing member. For these SSDs the operational parameters are not specified in this document. This document does not apply to: - SSDs upstream from/on/in domestic gas-consuming appliances which are installed downstream of domestic gas meters; - SSDs incorporated into pressure-regulating devices used in service lines with volumetric flow rate ≤ 200 m3/h at normal conditions and inlet pressure ≤ 5 bar.
BS EN 14382-2005+A1-2009由英國標準學會 GB-BSI 發布于 2006-02-23,并于 2006-02-23 實施。
BS EN 14382-2005+A1-2009 在中國標準分類中歸屬于: J16 閥門,在國際標準分類中歸屬于: 23.060.40 壓力調節器。
* 在 BS EN 14382-2005+A1-2009 發布之后有更新,請注意新發布標準的變化。
BS EN 14382-2005+A1-2009 帶上方澆口的通電閥門 由 BS EN 14382-2005 變更而來。
BS EN 14382-2005+A1-2009 帶上方澆口的通電閥門 由 BS EN 14382-2002 變更而來。
非常抱歉,我們暫時無法提供預覽,您可以試試: 免費下載 BS EN 14382-2005+A1-2009 前三頁,或者稍后再訪問。
點擊下載后,生成下載文件時間比較長,請耐心等待......
Copyright ?2007-2022 ANTPEDIA, All Rights Reserved
京ICP備07018254號 京公網安備1101085018 電信與信息服務業務經營許可證:京ICP證110310號