• <li id="ccaac"></li>
  • <table id="ccaac"><rt id="ccaac"></rt></table>
  • <td id="ccaac"></td>
  • <td id="ccaac"></td>
  • ISO/ASTM 51940:2004
    無生殖力昆蟲釋放計劃的劑量測定指南

    Guide for dosimetry for sterile insects release programs


     

     

    非常抱歉,我們暫時無法提供預覽,您可以試試: 免費下載 ISO/ASTM 51940:2004 前三頁,或者稍后再訪問。

    您也可以嘗試購買此標準,
    點擊右側 “購買” 按鈕開始采購(由第三方提供)。

    點擊下載后,生成下載文件時間比較長,請耐心等待......

     

    標準號
    ISO/ASTM 51940:2004
    發布
    2004年
    發布單位
    國際標準化組織
    替代標準
    ISO/ASTM 51940:2013
    當前最新
    ISO/ASTM 51940:2022
     
     
    適用范圍
    1 This guide outlines dosimetric procedures to be fol-lowed for the radiation sterilization of live insects for use in pest management programs. The primary use of irradiated, reproductively sterile insects is in the Sterile Insect Technique, where large numbers of sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide. Note 1—Dosimelry is only one component of a total quality control program to ensure that irradiated insects arc adequately sterilized and sufficiently competitive or otherwise suitable for their intended purpose. 2 This guide covers dosimetry in the irradiation of insects for these types of irradiators: self-contained dry-storage Cs or Co irradiators, large-scale gamma irradiators, and electron accelerators. Additional, detailed information on dosimetric procedures to be followed in installation qualification, opera-tional qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and ASTM Practice E2116 (self-contained dry-storage gamma facilities). 3 The absorbed dose for insect sterilization is typically within the range of 20 Gy to 600 Gy. 4 This guide refers, throughout the text, specifically to reproductive sterilization of insects. It is equally applicable to radiation sterilization of invertebrates from other taxa (for example, Acarina, Gastropoda) and to irradiation of live insects or other invertebrates for other purposes (for example, induc-ing mutations), provided the absorbed dose is within the range specified in 1.3. 5 This guide also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the insects have been irradiated. 6 This standard does not purport to address all of the safety concerns, if any. associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.

    ISO/ASTM 51940:2004相似標準


    誰引用了ISO/ASTM 51940:2004 更多引用





    Copyright ?2007-2022 ANTPEDIA, All Rights Reserved
    京ICP備07018254號 京公網安備1101085018 電信與信息服務業務經營許可證:京ICP證110310號

  • <li id="ccaac"></li>
  • <table id="ccaac"><rt id="ccaac"></rt></table>
  • <td id="ccaac"></td>
  • <td id="ccaac"></td>
  • 床戏视频