  • IEC 61810-7:2006
    機電式元件繼電器.第7部分:試驗和測量程序

    Electromechanical elementary relays - Part 7: Test and measurement procedures


    標準號
    IEC 61810-7:2006
    發布
    2006年
    發布單位
    國際電工委員會
    當前最新
    IEC 61810-7:2006
     
     
    被代替標準
    IEC 94/226/FDIS:2005 IEC 61810-7:1997
    適用范圍
    This part of IEC 61810 states the test and measurement procedures for electromechanical elementary relays. It covers basic considerations which are, in general, common to all types of electromechanical elementary relays. Supplementary requirements may be necessitated by specific designs or application. The test and measurement procedures of this standard are described as individual provisions covering a specific requirement. When combining them in a test programme, care must be taken (for example by suitable grouping of tested relays) to ensure that preceding tests do not devalue subsequent ones. Where in this standard the term “specified” is used, this means a prescription in the appropriate documentation for the relay, for example manufacturer’s data sheet, test specification, customer detail specification. For application within the IECQ system such prescriptions are contained in the detail specification as defined in Clause A.7 of QC 001001. NOTE 1 To improve the readability of this standard, the term “relay” is generally used in place of “electromechanical elementary relay”. NOTE 2 Requirements and tests related to the type testing of electromechanical elementary relays are contained in IEC 61810-1. For that purpose, the generally described test and measurement procedures of this standard have been prescribed in a more restricted and stringent form in IEC 61810-1. NOTE 3 Standards covering relays subjected to quality assessment in accordance with IECQ are compiled in the IEC 61811 series of publications.

    IEC 61810-7:2006相似標準


    推薦

    微量水分測量儀的產品特征

    7、便攜設計:儀器更輕,攜帶、使用方便。8、內置電源:內置可充電電池,一次充足可連續工作8小時。?微量水分測量儀產品特征1、密度繼電器校驗儀采用高性能十六位單片機進行檢測與控制,集成程度高。機電一體化設計,精度高,重復性好,可靠性高。2、配置了單色液晶屏軟鍵盤人機接口,操作簡單、界面美觀,所有參數及狀態一目了然。3、自動完成壓力測量20℃值轉換,從而完成了壓力、溫度間的動態自動補償。...

    說說微量水分測量儀主要技術特點

    7、便攜設計:儀器更輕,攜帶、使用方便。8、內置電源:內置可充電電池,一次充足可連續工作8小時。?微量水分測量儀產品特征1、密度繼電器校驗儀采用高性能十六位單片機進行檢測與控制,集成程度高。機電一體化設計,精度高,重復性好,可靠性高。2、配置了單色液晶屏軟鍵盤人機接口,操作簡單、界面美觀,所有參數及狀態一目了然。3、自動完成壓力測量20℃值轉換,從而完成了壓力、溫度間的動態自動補償。...

    微量水分測量儀特點

    7、便攜設計:儀器更輕,攜帶、使用方便。8、內置電源:內置可充電電池,一次充足可連續工作8小時。產品特征1、密度繼電器校驗儀采用高性能十六位單片機進行檢測與控制,集成程度高。機電一體化設計,精度高,重復性好,可靠性高。2、配置了單色液晶屏軟鍵盤人機接口,操作簡單、界面美觀,所有參數及狀態一目了然。3、自動完成壓力測量20℃值轉換,從而完成了壓力、溫度間的動態自動補償。...

    密度繼電器校驗儀的特性

    徹底解決了SF6氣體密度繼電器現場校驗難的問題  4、所有測試過程自動由儀器完成,不用人工干預,避免了繁瑣的人工氣路調節操作  5、漢字報表打印測試結果,并對試驗結果進行智能分析  6、能同時存儲50次試驗結果,并具有掉電數據保護功能,可隨時查詢打印以前的試驗結果  7、校驗過程中無需恒溫室,可以在任意有效溫度范圍內對SF6氣體密度繼電器、壓力表進行校驗  8、配有多種型號過渡接頭,大多數型號開關的密度繼電器不用拆卸即可進行現場校驗...