非常抱歉,我們暫時無法提供預覽,您可以試試: 免費下載 ASTM E572-2012 前三頁,或者稍后再訪問。
點擊下載后,生成下載文件時間比較長,請耐心等待......
5.1 This procedure is suitable for manufacturing control and for verifying that the product meets specifications. It provides rapid, multi-element determinations with sufficient accuracy to assure product quality. The analytical performance data included may be used as a benchmark to determine if similar X-ray spectrometers provide equivalent precision and accuracy, or if the performance of a particular spectrometer has changed.
5.2 It is expected that this standard will be employed by analysts knowledgeable in the field of X-ray fluorescence spectrometry and experienced in the use of the apparatus specified in this standard.
1.1 This test method2 covers the analysis of stainless and alloy steels by wavelength dispersive X-ray Fluorescence Spectrometry for the determination of the following elements:
Element | Range, Mass Fraction% |
Chromium | 2.0 to 25.0 |
Cobalt | 0.03 to 0.40 |
Copper | 0.05 to 3.50 |
Manganese | 0.3 to 5.0 |
Molybdenum | 0.15 to 3.5 |
Nickel | 0.20 to 35.0 |
Niobium | 0.05 to 1.3 |
Phosphorus | 0.01 to 0.03 |
Silicon | 0.05 to 0.20 |
Sulfur | 0.02 to 0.30 |
Titanium | 0.002 to 0.04 |
Vanadium | 0.03 to 0.25 |